Data Sheet
SORinc.com
TA Nuclear Qualified Pressure Detector
Models:
TA Nuclear Qualified Pressure Detector
Warranty:
Tested up to 200Mrad, the SOR TA nuclear-qualified pressure detector model is the super-rugged choice for containment. It withstands the most severe conditions including a loss of coolant accident. Built specific to LOCA requirements, it is qualified by a combination of testing and analysis that includes thermal aging, irradiation, mechanical/electrical cycling, and random multi-frequency.
- Ductile iron housing for LOCA tested to 200Mrad
- Threaded cover with a double environmental seal
- Vent connection provided if needed
- May be engineered to meet your specifications
- Pressure from 30” HgV to 1750 psi
Compliant
• 10CFR50, Appendix B
• ANSI N45.2
• NQA-1
• CSA N285.0 (Class 2 and 3 non-welded Category “F” type Fitting)
• CSA B51 Part 1
• We accept 10CFR21
Qualified by a Combination of Testing and Analysis
• IEEE-323-1974 & 1983
• IEEE-344-1975 & 1987
Audited by
• Nuclear Procurement Issues Committee (NUPIC)
• Nuclear Industry Assessment Committee (NIAC)
• Canadian Technical Standards & Safety Authority (TSSA) N285.0
• Tractebel Engineering SUEZ Certificate nr. 3696
Compliance and qualification depends on the individual instruments.